1 风力机 wind turbine
2 风力发电机组 wind turbine generator system ; WTGS(abbreviation)
3 风电场 wind power station ; wind farm
4 水平轴风力机 horizontal axis wind turbine
5 垂直轴风力机 vertical axis wind turbine
6 轮毂(风力机) hub (for wind turbines)
7 机舱 nacelle
8 支撑结构(风力机) support structure (for wind turbines)
9 关机(风力机) shutdown(for wind turbines)
10正常关机(风力机) normal shutdown (for wind turbines)
11紧急关机(风力机) emergency shutdown (for wind turbines)
12空转(风力机) idling(for wind turbines)
13锁定(风力机) blocking (for wind turbines)
14停机 parking
15静止 standstill
16制动器(风力机) brake (for wind turbines)
17停机制动(风力机) parking brake (for wind turbines)
18风轮转速(风力机) rotor speed (for wind turbines)
19控制系统(风力机) control system (for wind turbines)
20保护系统(风力发电机组) protection system (for WTGS)
21偏航 yawing
22设计工程 design situation
23载荷状况 load case
24外部条件(风力机) external conditions (for wind turbines)
25设计极限 design limits
26极限状态 limit state
27极限状态 limit state
28使用极限状态 serviceability limit states
29最大极限状态 ultimate limit states
30安全寿命 safe life
31严重故障(风力机) catastrophic failure (for wind turbines)
32潜伏故障 latent fault ; dormant failure
33风速 wind speed
34风矢量 wind velocity
35旋转采样风矢量 rotationally sampled wind velocity
36额定风速(风力机) rated wind speed (for wind turbines)
37切入风速 cut-in wind speed
38切出风速 cut-out wind speed
39年平均 annual average
40年平均风速 annual average wind speed
41平均风速 mean wind speed
42极端风速 extreme wind speed
43安全风速(拒用) survival wind speed(deprecated)
44参考风速 reference wind speed
45风速分布 wind speed distribution
46瑞利分布 RayLeigh distribution
47威布尔分布 Weibull distribution
48风切变 wind shear
49风廓线;风切变率 wind profile ; wind shear law
50风切变指数 wind shear exponent
51对数风切变率 logarithmic wind shear law
52风切变幂律 power law for wind shear
53下风向 downwind
54上风向 upwind
55 阵风 gust
56粗糙长度 roughness length
57湍流强度 turbulence intensity
58湍流尺度参数 turbulence scale parameter
59湍流惯性负区 inertial sub-range
60互联(风力发电机组) interconnection (for WTGS)
61输出功率(风力发电机组) output power (for WTGS)
62额定功率(风力发电机组) rated power (for WTGS)
63最大功率(风力发电机组) maximum power (for WTGS)
64电网联接点(风力发电机组) network connection point (for WTGS)
65电力汇集系统(风力发电机组) power collection system (for WTGS)
66风场电气设备 site electrical facilities
67功率特性 power performance
68净电功率输出 net electric power output
69功率系数 power coefficient
70自由流风速 freestream wind speed
71扫掠面积 swept area
72轮毂高度 hub height
73测量功率曲线 measured power curve
74外推功率曲线 extrapolated power curve
75年发电量 annual energy production
76可利用率(风力发电机组) availability (for WTGS)
77数据组(功率性测试) data set (for power performance measurement)
78精度(风力发电机组) accuracy (for WTGS)
79测量误差 uncertainty in measurement
80分组方法 method of bins
81测量周期 measurement period
82测量扇区 measurement sector
83日变化 diurnal variations
84桨距角 pitch angle
85距离常数 distance constant
86试验场地 test site
87气流畸变 flow distortion
88障碍物 obstacles
89复杂地形带 complex terrain
90风障 wind break
91声压级 sound pressure level
92声级 weighted sound pressure level ; sound level
93视在声功率级 apparent sound power level
94指向性(风力发电机组) directivity (for WTGS)
95音值 tonality