Technical consideration for a long period safety operation of a 460t/hcirculating fluidized boiler
Zhao Dexin
(Huasheng Jiangquan Power Plant Co. ltd., Linyi 276017)
Abstract:The 460t/h circulating fluidized bed boiler (CFB) of Jiangquan power plant had operated with a long period of beyond 300 days. The paper introduces how the boiler gets such an excellent achievement under nominal parameter through the processes from auxiliary equipments purchase, installation, boiler test, technical retrofit as well as operation optimization etc.
Key words:460t/h, CFB boiler, continue running, 300 days, technical
1 夯实基础、迎接挑战
3#机组从2006 年12 月24 日连续安全运行至今,已超过300 天,下面介绍一下我们实现大型CFB机组长周期安全运行的做法和体会。
1) 概述
火力发电厂机组运行的周期长短关键取决于锅炉,从有关资料证明,锅炉的事故率占55%,要确保机组长周期运行必须从锅炉抓起,特别是循环流化床锅炉,近几来年来我国的大型CFB锅炉处于起步研制阶段,无论从设计,制造、调试、运行等方面都存在经验不足、问题多的局面,给发电企业带来困惑,同时也带来挑战和机遇,通过全国电力行业专家和电厂同仁们的共同努力,大型CFB机组安全运行情况一天比一天好转。我公司先投运的1#、2#机组投产初期,同样也存在这样或那样的问题,机组不能长周期运行,存在水冷壁管磨损爆管、风帽磨损、漏渣、冷渣器排渣困难、原煤斗落煤管堵煤严重、风机轴承温度高等问题,此时我厂3#机组正在筹建安装过程中,如何实现新机组安装后能安全经济长周期运行,是摆在领导及全体职工面前的首要课题,3#机组决不能走1#、2#机组的老路,因此公司提出了“夯实基础、迎接挑战,改造创新,确保长周期运行”的奋斗目标。