图13高压直流控制设备相互联结示意图B
半导体阀……………………………………………………………………………………4.15
臂………………………………………………………………………………………………3.3
C
超前角(β)………………………………………………………………………………5.24
重叠角(υ)………………………………………………………………………………5.25
触发…………………………………………………………………………………………5.10
穿通…………………………………………………………………………………………5.39
D
大地回路……………………………………………………………………………………6.16
单阀单元……………………………………………………………………………………4.11
单极高压直流系数…………………………………………………………………………6.9
单向高压直流系数…………………………………………………………………………6.6
导通间隔……………………………………………………………………………………5.29
导通状态……………………………………………………………………………………5.12
等间隔触发控制………………………………………………………………………………8.2
等延迟角控制…………………………………………………………………………………8.3
电网换相…………………………………………………………………………………3.13
多重阀单元…………………………………………………………………………………4.12
多端高压直流输电系统……………………………………………………………………6.4
多端控制…………………………………………………………………………………8.5
多阳极阀…………………………………………………………………………………4.14
E
二端高压直流输电系统………………………………………………………………………6.3
二极管阀…………………………………………………………………………………4.16
F
阀…………………………………………………………………………………4.5
阀避雷器…………………………………………………………………………………4.24
阀闭锁…………………………………………………………………………………5.19
阀保护…………………………………………………………………………………8.20
阀侧绕组…………………………………………………………………………………4.39
(阀)主端子…………………………………………………………………………………4.21
阀电抗器…………………………………………………………………………………4.32
阀电压…………………………………………………………………………………5.9
阀基…………………………………………………………………………………4.8
阀击穿…………………………………………………………………………………5.43
阀监测…………………………………………………………………………………8.19
阀解锁…………………………………………………………………………………5.21
阀均压器…………………………………………………………………………………4.36
阀控制…………………………………………………………………………………8.16
阀控制脉冲…………………………………………………………………………………8.11
阀组件…………………………………………………………………………………4.6
阀阻尼电路…………………………………………………………………………………4.31
反向…………………………………………………………………………………5.4
反向电流…………………………………………………………………………………5.6
反向电压…………………………………………………………………………………5.8
反向击穿…………………………………………………………………………………5.45
反向阻断间隔…………………………………………………………………………………5.32
反向阻断状态…………………………………………………………………………………5.15
非均一桥…………………………………………………………………………………3.8
非可控换流臂…………………………………………………………………………………3.5
G
高压直流换流站……………………………………………………………………………6.11
高压直流耦合系统……………………………………………………………………………6.5
高压直流输电系统……………………………………………………………………………6.2
高压直流输电线路……………………………………………………………………………6.13
高压直流输电线路极线………………………………………………………………………6.14
高压直流系统……………………………………………………………………………6.1
高压直流系统的极……………………………………………………………………………6.8
汞弧阀……………………………………………………………………………4.13
关断间隔……………………………………………………………………………5.27
过电流分流器……………………………………………………………………………4.40
H
换流…………………………………………………………………………………………3.1
换流臂…………………………………………………………………………………………3.3
换流变压器……………………………………………………………………………………4.37
换流单元…………………………………………………………………………………………4.1
换流单元保护…………………………………………………………………………………8.14
换流单元触发控制……………………………………………………………………………8.10
换流单元分接开关控制………………………………………………………………………8.12
换流单元监测…………………………………………………………………………………8.13
换流单元控制…………………………………………………………………………………8.9
换流单元顺序控制……………………………………………………………………………8.15
换流电路………………………………………………………………………………………3.2
换流器…………………………………………………………………………………………4.3
换流器闭锁……………………………………………………………………………………5.20
换流器解锁……………………………………………………………………………………5.22
换流桥…………………………………………………………………………………………4.2
换流站…………………………………………………………………………………………6.11
换流站极………………………………………………………………………………………6.12
换流站控制……………………………………………………………………………………8.7
换相…………………………………………………………………………………………3.12
换相电感……………………………………………………………………………………3.16
换相电抗………………………………………………………………………………………3.17
换相电流………………………………………………………………………………………3.14
换相电压………………………………………………………………………………………3.15
换相失败………………………………………………………………………………………5.33
换相数(q)……………………………………………………………………………………3.20
换相组…………………………………………………………………………………………3.18
J
极…………………………………………………………………………………………6.8
极控制…………………………………………………………………………………………8.8
继发逆弧………………………………………………………………………………………5.42
交流滤波器……………………………………………………………………………………7.1
接地极…………………………………………………………………………………………7.8
接地极引线………………………………………………………………………………………7.9
金属回路………………………………………………………………………………………6.15
晶闸管阀………………………………………………………………………………………4.17
晶闸等级………………………………………………………………………………………4.7
均流器…………………………………………………………………………………………4.35
均一桥…………………………………………………………………………………………3.7
K
开通…………………………………………………………………………………………5.11
可控阀………………………………………………………………………………………4.18
可控换流臂…………………………………………………………………………………3.4
可逆高压直流系统…………………………………………………………………………6.7
控制方式………………………………………………………………………………………8.1
控制系统接地网……………………………………………………………………………7.7
L
临界关断间隔…………………………………………………………………………………5.28
M
脉波数(p)……………………………………………………………………………………3.19
脉冲传递系统…………………………………………………………………………………8.17
脉冲分配系统…………………………………………………………………………………8.18
门极脉冲……………………………………………………………………………………5.17
N
逆变……………………………………………………………………………………5.2
逆弧…………………………………………………………………………………………5.11
逆火…………………………………………………………………………………………5.40
P
旁路…………………………………………………………………………………………3.9
旁路臂…………………………………………………………………………………………3.10
旁路对…………………………………………………………………………………………3.11
旁路阀…………………………………………………………………………………………4.20
旁路开关………………………………………………………………………………………4.41
Q
桥…………………………………………………………………………………………3.6
桥避雷器………………………………………………………………………………………4.25
桥式换流联结…………………………………………………………………………………3.6
S
栅极脉冲………………………………………………………………………………………5.16
失触发…………………………………………………………………………………………5.36
失通…………………………………………………………………………………………5.37
双极高压直流系统…………………………………………………………………………6.10
W
网侧绕组………………………………………………………………………………………4.38
误触发…………………………………………………………………………………………5.34
误通…………………………………………………………………………………………5.35
X
系统控制………………………………………………………………………………………8.4
相对地避雷器…………………………………………………………………………………4.27
相间避雷器……………………………………………………………………………………4.26
相位控制………………………………………………………………………………………5.16
Y
延迟角(α)……………………………………………………………………………………5.23
阳极半桥………………………………………………………………………………………4.4
阳极电抗器……………………………………………………………………………………4.33
阳极端子………………………………………………………………………………………4.22
阴极半桥………………………………………………………………………………………4.4
阴极电抗器……………………………………………………………………………………4.34
阴极端子………………………………………………………………………………………4.23
冗余晶闸管……………………………………………………………………………………4.9
冗余晶闸管因数………………………………………………………………………………4.10
裕度角(γ)…………………………………………………………………………………5.26
Z
载波滤波器…………………………………………………………………………………7.11
站接地网……………………………………………………………………………………7.6
整流……………………………………………………………………………………5.1
正向……………………………………………………………………………………5.3
正向电流……………………………………………………………………………………5.5
正向电压……………………………………………………………………………………5.7
正向击穿……………………………………………………………………………………5.44
正向阻断间隔…………………………………………………………………………………5.31
正向阻断状态…………………………………………………………………………………5.14
直流冲击电容器………………………………………………………………………………7.5
直流电抗器……………………………………………………………………………………7.2
直流滤波器……………………………………………………………………………………7.3
直流母线避雷器……………………………………………………………………………4.28
直流线路避雷器……………………………………………………………………………4.29
直流阻尼电路………………………………………………………………………………7.4
直通……………………………………………………………………………………5.38
中性母线…………………………………………………………………………………7.10
中性母线避雷器………………………………………………………………………………4.30
主阀……………………………………………………………………………………4.19
主控制……………………………………………………………………………………8.6
阻断间隔……………………………………………………………………………………5.30
阻断状态……………………………………………………………………………………5.13