Lurkingintheshadowsofeventhemostunsuspectingoperations—fromcorporatetocommercialtoindustrialfacilities—isaconditionknownaspoorvoltagequality,ahiddenexpensethattypicallygoesundetectedandundiagnoseduntilcostlyfailuresoccur.Voltageeventsinterruptsensitiveprocesses,shortentheusefullifeofequipment,andcausecomputerandcommunicationsproblems.Oftentimes,thesedisturbancestriggerneedlessexpensesintheformofimplementedsolutionstomisdiagnosedproblems.Unlessthesourceoftheproblemiscorrectlyidentifiedanditscausefoundandrepaired,thecostsandtimerequiredtosolvetheproblemaddupquickly.
endparagraphbeginparagraph
Definedintermsofmagnitude(amplitude)andduration(length),voltageevents—appearingintheformofsags,swells,impulses,andtotalharmonicdistortion—canaffectequipmentperformanceindifferentways.Typically,theultimateimpactofsucheventsisdeterminedbythesensitivityoftheequipmentonthebranchcircuit.
endparagraphbeginparagraph
- Voltagesags
Asagisaperiodoflowvoltage.Minorsagsoccurfrequently,sometimeswithoutdisturbingequipmentperformance.Majorsags,ontheotherhand,alwaysdisturbequipmentperformance.Sagsoccurformanyreasons,includingvoltagedropcausedbylongrunsofwire,switchingloads,poorwiring,andoverloadedbranchcircuits.
- Voltageswells
Aswellisaperiodofhighvoltage.Swellshaveseriousimpactonequipmentfunction;however,theyarenotascommonassags.Bothminorandmajorswellsaffectequipmentperformance.
- Impulses
Animpulseisashortburstofenergythatlastsforlessthanacycle.Impulsesrangeinmagnitudefromtwicethenominalvoltagetoseveralthousandvolts.Noteveryimpulsehasanimpactonequipmentperformance.However,whenimpulsesoccurrepeatedlyovertime(orwhentheenergylevelisveryhigh),animpulsecancauseequipmentdegradationorevenimmediatefailure.
- Harmonics
ACvoltageisasinewavethatrepeats60timespersecond(Hertz=cycles/second).Thisisthefundamentalfrequency.Harmonicsarealternatefrequenciesthatdistortthesinusoidalwaveform.Totalharmonicdistortion(THD)ismeasuredasapercentageofthefundamentalfrequency.Equipmentrunswellonvoltagethatisaclean(orslightlydistorted)sinewave.Highlevelsofdistortionmaycauseequipmentproblems.Onsingle-phasebranchcircuits,levelsofTHDgreaterthan5to8shouldbeinvestigated.
endparagraphbeginparagraph
Inmanycases,uponfurtherinvestigationbyapowerqualityprofessional,problemsthathaveexistedforyearsaretracedbacktoundetectedvoltageeventscausedbytheculpritsoutlinedabove.Aftervoltageinterruptionsmaketheirpresenceknown,thefirstquestionend-userstypicallywantansweredis,“Howdidtheygetstartedinthefirstplace?”
endparagraph
Howdovoltageeventsoccur?
beginparagraph
Thesourceof85ofallvoltageevents,causedbyinadequatesupply,undersizedwiring,oranoverloadedcircuit,originateswithinafacility,notontheelectricutilitysystem.Frequently,problemsarisewhenequipmentturns“on”or“off”onthesamecircuit.Environmentalchanges,suchaslightningstorms,highwinds,flooding,physicaldamage,utilityoperations,orneighboringfacilities,alsocanaffectvoltage.Whenyouconsiderthatvoltagequalityalsochangeseverytimeanewpieceofequipmentisinstalledinafacility—orinaneighboringfacility—thingsbecomeevenmorecomplicated.
endparagraphbeginparagraph
Someperceivedpowerqualityproblems,however,havenothingtodowiththesupplyofvoltage.Instead,youcantracethembacktohumanerror.Forinstance,custodialcrewsunpluggingequipmenttocleanaroundthem,andpaintingcrewsdisconnectingthegroundrod,arebothexamplesofroutineactivitiesthatcanaffectvoltagequality.
endparagraph
Howdoeventsaffectequipment?
beginparagraph
Electricalequipmentisdesignedtoworkatnominalvoltage( /-10).Althoughequipmentmaynotfailthefirsttimeaneventoccurs,excessivestressfromrepeatedvoltageeventscancausedamageovertime.Whenvoltageisoutsideofequipmentdesignspecifications,forexample,equipmenthastoworkharder,runhotter,orinsulationmayhavetowithstandextremevoltagelevels.Forinstance,arefrigeratorisdesignedtooperatebetween108VACand132VAC—thatis,atypicalvoltagerangeforanominal120Vpieceofequipment.Ifvoltagerunsconsistentlybelow108Vonthecircuitpoweringtherefrigerator,thecompressormotorwillrunhotter,reducingitsoperationandservicelife.
endparagraphbeginparagraph
Sagsarethemostprevalentpowerqualityissueforequipment.Momentarysagsmaynotaffecttherefrigeratorreferencedabove,buttheywillcauseproblemsformoresensitiveequipment,suchascomputers.Thegreaterthevoltagesag,thegreaterthelikelihoodofdamage.Similarly,thegreaterthenumberofsagsoccurring,thegreaterthechanceoffailureordamage.
endparagraphbeginparagraph
Althoughvoltageswellsoccurlessfrequentlythansags,evenrelativelyminorswellscandamageequipment.Therefore,theyrequireimmediateattention.Thelongeraswell''sduration,themoreextensivethedamagewillbe.Anexampleherewouldbealargemotorcreatingvoltagesagsbydrawinghighinrushcurrents.Whenthemotorisstoppedabruptly,voltageswellsaregenerated.Leftuncorrected,thesesagsandswellswillleadtocomputerdisruptionsandfrequenthardwarereplacementinthefacility.
endparagraphbeginparagraph
THDcanproduceexcessiveheat,generateelectro-magneticinterferenceincommunicationscircuits,andcauseelectroniccontrolstofail.Non-linearloads,suchasPCs,copyingmachines,andvariable-frequencydrives,createharmoniccurrentsthatdistortthevoltagesinewave.Themoreelectronicdevicesonacircuit,thegreaterthelikelihoodofseverevoltagedistortion.Agoodexampleofsuchaprobleminvolvedahospitaltechnicianwhotestedacircuitfortwodaysbeforeinstallingpatientmonitoringequipment.Oneinstanceofvoltageharmonics,amountingto5.2THD,wasnoted.RecognizingthislowlevelofTHDwouldn''tcauseaproblem,thetechnicianinstalledthepatientmonitoringdevice.Withinhours,thedevicefailed.ThetechnicianreviewednewdatatofindaTHDeventreaching10.2.Furtherinvestigationusingacircuitanalyzerandlong-termrecordersfoundtherewereseveralnon-linearloadspluggedintothesamebranchcircuitasthepatientmonitoringdevice.Whencertaincombinationsoftheseloadswereonsimultaneously—alongwiththenewequipment—excessiveharmonicsflowed,causingadistortedvoltagewaveformandsporadicshutdownofthedevice.
endparagraph
Howtotestvoltagequality
beginparagraph
Thereareavarietyofvoltagemonitoringdevicesonthemarketforyoutochoosefromtodiagnosevoltageproblems.Theserangefromhigh-endpowerqualityanalyzersyoucanuseattheserviceentrancetosimplemonitorsthatconnectatthebranchlevel.
endparagraphbeginimage
Equipmentoperatingonvoltagelevelsoutsideof“normal”rangeswon’toperateforlong.endimagebeginparagraph
Sometesterscomewithpre-loadedmonitoringstandardsbasedonthemostwidelyusedinternationalvoltagestandards,suchasCBEMA,ITIC,IEEE519or1159.1.Differentapplicationsrequiredifferentvoltagequalitystandards.Somearequitestringentandwillrecordmanyevents;othersarelessstringent,applyingtolerancesdesignedformodern,morerobustloads,resultinginfewerout-of-toleranceeventstoberecorded(Table).Theimportantthingtonotehereisthatyouthoroughlyunderstandhowthemonitoryou"reusingworksandtheparametersit"susingtomakemeasurements.
endparagraphbeginparagraph
Whenitcomestovoltagequality,thereisnosuchthingasacoincidence.Sowhileyou''retesting,carefullyexaminethesimultaneousoperationofequipmentasalikelycauseofvoltageevents.Notedatesandtimesofnuisanceevents,andrecordtheeventrecordsaspartofnormaloperations.Finally,alwaysconsultyourlocalelectricutilityforresourcestohelpdiagnosepowerproblems,improveefficiency,andavoidusagepenalties.
endparagraphbeginparagraph
Gregorecisgroupmanager,IDEALTest&Measurement,Sycamore,Ill.